Customization: | Available |
---|---|
Theory: | Voltage Relay |
Usage: | Communication Relay |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Over voltage | Under voltage | Action delay | Rated supply voltage code | Rated supply voltage | Working voltage range | Setting range |
ZHRV5-01 | >U or <U Selectable by knob |
0.1s~10s | D12 | DC12V | DCV-20V | DC9V-15V | |
AD48 | AC/DC24V-48V | AC/DC15V-100V | AC/DC20V-80V | ||||
AD240 | AC/DC110-240V | AC/DC50V-270V | AC/DC65V-260V | ||||
A220 | AC 160V-270V | AC160V-270V | AC180V-260V | ||||
ZHRV5-02 | √ | √ | D12 | DC12V | DCV-20V | DC9V-15V | |
AD48 | AC/DC24V-48V | AC/DC15V-100V | AC/DC20V-80V | ||||
AD240 | AC/DC110-240V | AC/DC50V-270V | AC/DC65V-260V | ||||
A220 | AC 160V-270V | AC160V-270V | AC180V-260V |