Customization: | Available |
---|---|
Usage: | Household Appliances Relay, Communication Relay, Lathe Relay |
Phase: | 2 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Functions:
1.Over-voltage protection
2.Under-voltage protection
3.Over-current protection
4.Automatic recovery
5.Voltage display(voltage measurement)
6.Current display (current measurement)
7. Voltage calibration: Voltage +-9.5% adjustable.
8. Restore factory settings: press the down button for more than 12s
9. Fault inquiry: Press the UP button from more than 12S
Product Parameters:
1.Model number:TOSVA-16
2.Power supply:90-300VAC 50/60Hz
3.Max.Loading power: 1~16A Adjustable(default:16A)
4.Over-voltage protection value range:100V~300~OFF(default:270V)
Over-voltage recovery voltage range: 95V--295V(default:265V)
Over-voltage protection action time:0.1s~30s(default value:0.5s)
Over-voltage recovery delay time:1s~500s(default:30s)
5.Under-voltage protection value range:80V--210V --OFF(default:170V)
Under-voltage recovery voltage range:85V--215V (default:175V)
Under-voltage protection action time:0.1s~30s(default:0.5s)
Under-voltage recovery delay time:1s~500s(default:30s)
6.Over-current adjustment range:1-16A (default:16A)
Over-current action range:0.1~30 second (default:0.5s)
Over-current recovery delay time:1s~500s(default:30s)
7.Power-on delay time:1s~500s(default:10s)
8.Power consumption : <2W
9.Electric machinery life : 100,000 times
10.Installatin:35mm DIN rail
Setup Menu | |||||||
Code | Option | Set range | Default | Code | Option | Set range | Default |
P1 | Power-on delay | 1-999 | 5S | P14 | Rapid power failure protection | ON/OFF | ON |
P2 | Recovery delay | 1-999 | 30S | P15 |
Display mode | 1:Standards 2:Manual switch 3:Automatic switch |
1:Standards |
P3 | Overvoltage | 130-300 | 270V | ||||
P4 | Overvoltage recovery value | 125-295 | 265V | ||||
P5 | Undervoltage | 80-210 | 170V | P16 | Automatic reset | ON:Self-recovery OFF:Manual recovery |
ON |
P6 | Undervoltage recovery value | 85-215 | 175V | ||||
P7 | Overvoltage action delay | 0.1-10.0 | 0.5S | P17 | Action/knife mode | ON/OFF | ON |
P8 | Voltage correction | -10%-+10% | 0V | ||||
P9 | Overcurrent | 1-40 1-63 |
40A 63A | P18 | Energy saving mode | ON/OFF | OFF |
P10 | Overflow as delay | 0.1-10.0 | 1.0S | ||||
P11 | Continuous overcurrent counting | 0-20 | 0 times | P19 | Setup lock password | 000-999 | 112 |
P12 | Current correction | -10%-+10% | 0A | P20 | Change password lock | 000-999 | 112 |
P13 | Frequency correction | -2.5%-+2.5% | 0Hz |