Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay

Product Details
Customization: Available
Theory: Voltage Relay
Usage: Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay, Motor Protective
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
500000 RMB
Plant Area
101~500 square meters
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
  • Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
Find Similar Products

Basic Info.

Model NO.
ZHRV2-36G
Phase
1
Load
Micro Power Relay
Protective Characteristics
Enclosed Relay
Action Principle
Electronic Type
Size
Miniature
Type
Electric Parameter Relay
Rated Supply Frequency
50/60Hz
Rated Control Supply Voltage
AC220V
Contact Configuration Capacity(a)
32A, 40A, 63A, 80A
Reset Delay
1s
Power on Delay
2s
Under-Voltage Action Value
175V
Over-Voltage Action Value
265V
Under-Voltage Reset Value
180V
Over-Voltage Reset Value
257V
Transport Package
Stardard Packing
Specification
79.4*36*65.5mm
Trademark
AKMAN
Origin
Zhejiang China
HS Code
8536490000
Production Capacity
10000PCS/Week

Product Description

Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay
Applications
Used in home and villa single-phase control system,when the power supply is abnormal(voltage too high or too low),cut off the power to protect electrical equipment from damage.

Features:
Built-in microprocessor,true RMS measurement,voltage measurement accuracy ≤1%.Knob setting,LED indicator shows working status.Use(magnetic latching)relay to achieve products low-power.DIN-rail mounting.
 
Model Description
Household AC220V Self-Resetting Over Voltage and Under Voltage Protection RelayZHRV2-36G panel description:
Household AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay Technical Parameters
Rated supply voltage Ac220V
Rated supply frequency 50/60HZ
Contact Configuration capacity(A) 32A,40A,63A,80A Resistive
Maximum load power 7kVA(40A),13 kVA(63A),17 kVA(80A)
Over-voltage action value 265V  
Over-voltage reset value 257V  
under-voltage action value 175V  
under-voltage reset value 180V    
Action delay 0.1s  
Power on delay 2s     
Reset delay 1s   
Voltage measurement error ≤1%
Delay error ±10%+0.1s
Knob setting accuracy ±1V
Rated insulation voltage 415V
IP Class IP20
Class of pollution 3
Electrical Life 105
Mechanical life 106
Altitude ≤2000m
Allowable relative humidity ≤50%(40 oC)(No condensation)
DIN rail Standard (width)35mm(IEC/EN60715)
 
Operating Instructions
1.Wire the protector according to the indicator IN and OUT directive.
2.When the protector is with normal supply voltage, yellow R/T indicator stays light on, relay implements output action; otherwise protector showsfaultwhile relay gets disconnected.
3.In case supply voltage goes over the set voltage operating value, yellow R/T indicator flickers and red U > indicator light-on. When fault time islonger than the set delay time, output relay gets disconnected, R/T indicator light-off. And if supply voltage is lower than undervoltage operating value, yellow R/T indicator flickers and red U< light-on. Also when fault time is longer than the set delay time, output relay gets disconnected, R/T indicator light-off.
4.When overvoltage fault protection is on and supply voltage is lower than overvoltage reset value, output relay actuates and R/T indicator light-on;
when overvoltage fault protection is on and supply voltage ishigher than undervoltage reset value, output relay actuates and R/T indicator light-on.
5.When supply voltage is lower than 150V, protector activates right away with no action delay;meanwhile,yellow R/T indicator light-off, red U< indicator light-on,and output relay gets disconnected.
6.Wiring terminal: N represents Zero Line, L represents Live wire, please do not mix up.
7.To avoid heating of contact from heavy current, please make sure the screw nail on the wiring terminal is tightened so as to prevent protector burning-up or other induced disaster.
Household AC220V Self-Resetting Over Voltage and Under Voltage Protection RelayHousehold AC220V Self-Resetting Over Voltage and Under Voltage Protection Relay

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier