• Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
  • Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
  • Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
  • Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
  • Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
  • Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay

Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay

Theory: Electromagnetic Relay
Usage: Household Appliances Relay, Communication Relay
Phase: 3
Electricity Type: Ac
Load: Micro Power Relay
Protective Characteristics: Enclosed Rlay
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
ZHRV3-05
Action Principle
Electronic Type
Size
Miniature
Type
Voltage Relay
Rated Frequency
50Hz/60Hz
Name
Voltage Monitoring Relay
Key
Voltage Control Relay
DIN Rail Standard
Width 35mm
Phase Failure and Phase Sequence
<0.5s
Transport Package
Standard Packing
Specification
91.4*36*68mm
Trademark
AKMAN
Origin
China
HS Code
8536490000
Production Capacity
2000PCS/Week

Product Description

Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay

Technical parameters: 
Rated supply voltage P-P: AC 3× 208--3× 440V; P-N: AC 3× 120--3× 254V
Rated supply working voltage range P-P:AV 166V--528V;P-N:AC 96V-329V
Rated supply frequency 50Hz/60Hz
Voltage measurement error ≤1% (Entire setting range)
Delay error ±10%+0.1s
Rated working voltage selection M440:208-220-230-240-380-400-415-440(V)(P-P)
M254:120-127-132-138-220-230-240-254(V)(P-P)
Measuring range AC 166V--528V; AC 96V--329V
Measurement frequency range 45Hz-65Hz
Vlotage threshold range 2%-20%
Unbalance threshold range 5%-15% of rated voltage
Fixed hysteresis rate 2%
Action delay range 0.1s-10s
Reset delay range 0.1s-10s
Knob setting accuracy 1% scale value
Phase failure and phase sequence ≤0.5s
Rated insulation voltage 440V
Contact configuration capacity(A) 2 C/O 8A;1 C/O+1 C/O 5A
IP Class IP20
Class of pollution 3
Electrical Life 105
Mechanical life 106
Altitude ≤2000m
Allowable relative humidity ≤50%(40ºC)(No condensation)
Use category AC-15
Contact capacity Ue/le:250V/1.5A
Output type 2 C/O;1C/O+1 C/O
DIN rail Standard Width 35mm(IEC/EN60715)

Model selection table
Model Overvoltage Undervoltage Asymmetry Trip delay Phase sequence Phase failure Operating voltage Reset time Output Contact Rated operating
Selectable voltage(Un)
ZHRV3-01 - - - 0.1~10s 0.1~10s Z: 2 C/O, M: Mobus+1 C/O A440:         AC(3phase 3wire) 208V, 220V      230V, 240V        380V, 400V 415V, 440V      AN254:       AC(3phase 4wire) 120V, 127V        132V 138V        220V, 230V      240V, 254V
ZHRV3-02 2%~20% - 5%~15% 0.1~10s 0.1~10s
ZHRV3-03 - - - 0.1~10s - 0.1~10s
ZHRV3-04 2%~20% 2%~20% - 0.1~10s - 0.1~10s Z: 2C/O, C: 1C/O+1C/O, Mobus+1C/O
ZHRV3-05 2%~20% 2%~20% - 0.1~10s - 0.1~10s Z: 2C/O, M: Mobus+1C/O
ZHRV3-06 2%~20% 2%~20% 5%~15% 0.1~10s 0.1~10s
ZHRV3-07 2%~20% 2%~20% 5%~15% 0.1~10s 0.1~10s
ZHRV3-08 15% 2%~20%   2s 2s
ZHRV3-09 15% -   2s 2s
ZHRV3-10 15% 15% 8% 2s 2s
ZHRV3-11 15% 15% 8% 2s 2s
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
Features:

Microprocessor base.
Modular design, 36mm width
True RMS measurement, measuring accuracy&less; 1%.
Wide frequency range(45-65Hz) measurement
8 nominal operating voltage selectable
Reset delay adjustable
LED indication for control state
Communication through Modbus module
Applications:

Protection electromechnical device against voltage faults. Protection electromechnical device against reverse running. Protection against a driving load (phase failure) Normal/emergency power supply switching.
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay


Function diagram
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
Wiring Diagram
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control RelayTerminal diagram
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay

Dimensions(mm)

Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
More Products

Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control Relay
Voltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control RelayVoltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control RelayVoltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control RelayVoltage Protection Relay AC Voltage Controlled Relay Over Under Voltage Control RelayQ1.Are you a factory or trading company ?
A:We are a factory founded in 2010 and have over 10 years'OEM and international trading experience .

Q2.What's your main product?
A:Our main products are time Relay, voltage Relay, motor protector, current relay,solid state relay

Q3.Do you accept OEM or ODM?
A:Of course.

Q4.What's your main payment term?
A:T/T ,LC ,D/P.

Q5.Any quality guarantee or after-sales service?
A:All the products have 2 years' Guarantee. If any quality complaint , we will give out solution within 5 days


Q6.Can sample fee be returned back to me ?
A:Sample amount can be deducted from your bulk order payment when order quantity is over 1000 pieces at the first time.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other
Registered Capital
500000 RMB
Plant Area
101~500 square meters