Model NO.
ZHRV2
Electricity Type
Ac
Size
Miniature
Type
AC Contactors
Rated Frequency
50Hz/60Hz
Trip Time for PTC Faults
<0.5s
Conventional Thermal Current
5A
Voltage Measuring Error
<1%(Over The Whole Range)
Rated Supply Voltage
220V, 230V, 240V, 380V, 400V, 415V ± 10%
Trip Time for Phase Failure or Incorrect
≤ 1s
Time Delay Error
± 10%, + 0.1s
Utilisation Category
AC-15, DC-13
Transport Package
Standard Packing
Trademark
AKMAN
Origin
China
HS Code
8537109090
Production Capacity
1000PCS/Week

Product Description


ZHRV series Electromechnical Motor Protective Relay and Three phase AC Voltage monitoring Relay and Protector
Feature:
1, Microprocessor base
2, True RMS measurement, measuring accuracy≤ 1%
3, Can be Used for monitoring circuit of single phase, two phase,
Three phase three wire or three phase four wire
4, LED indication for control state
5, 36mm width
 

Application:
1, Protection electromechnical device against voltage faults
2, Protection against a driving load (phase failure)
3, Normal/emergency power supply switching
4, Protection electromechnical device against reverse running

Working range:
Factory control system, power compensation system, switchboard, air-conditioning system, motor controlling.

Functions:
Overvoltage monitoring, Undervoltage monitoring. Phase failure monitoring
Model Overvoltage monitoring Undervoltage monitoring Asymmetry protection Phase sequence protection  Phase failure protection
setting range time-delay range setting range time-delay range setting range time-delay range
ZHRV2-01 N N N N N N Y Y
ZHRV2-02 N N N N 8% 2s Y Y
ZHRV2-03 1.05-1.30 0.1-10s 0.70-0.95 0.1-10s N N N Y
ZHRV2-04 1.05-1.30 0.1-10s 0.70-0.95 0.1-10s N N Y Y
ZHRV2-05 1.15 2s 0.85 2s N N Y Y
ZHRV2-06 N N N N 5%-15% 0.1-10s Y Y
ZHRV2-07 1.05-1.30 0.1-10s 0.70-0.95 0.1-10s 5%-15% 0.1-10s N Y
ZHRV2-08 1.05-1.30 0.1-10s 0.70-0.95 0.1-10s 5%-15% 0.1-10s Y Y
ZHRV2-09 1.15 2s 0.85 2s 8% 2s N Y
ZHRV2-10 1.15 2s 0.85 2s 8% 2s Y Y
ZHRV2-11 1.15 2s 0.85 2s 8% 3s Y Y
Note: 1. Y the function is available, N the function is not available
          2. In the circuit of three phase four wire, the relay which have no phase sequence protection function can be used to protect single phase or two phase circuit.                          
          3. All models relay can be adjusted in 220V/230V/240V or 380V/400V/415V except RV2 -07, RV2 -08        

Description of panel diagram: 
I. Function indicator lamp: 
a. Power indicator lamp: indication of power supply for relay
b. Normal: no fault of relay indicated
c. Operation: output relay operation indication
d. Over-voltage: over-voltage fault indication
e. Under-voltage: under-voltage fault indication
f. Phase dislocation: indication of input phase sequence errors
g. Phase failure: indication of phase failure fault
h. Unbalance: three-phase imbalance fault indication
i. Over-voltage/under-voltage: in case of over-voltage fault, the indicator lamp would be constantly ON; in case of under-voltage, 
   the fault indicator lamp would flash.
j. Over-voltage/under-voltage/recovery: when overvoltage fault occurs, the indicator lamp would flash at a high frequency (flash once every 
  0.3s); in case of under-voltage fault, the indicator lamp would flash at a low frequency (once every 1.5s); in case of recovery delay, the indicator        lamp would be constantly ON.
II. Setting knob: 
a. ×Ue: knob for setting of threshold values of over-voltage (1.05~1.30)  or under-voltage (0.70~0.95)
b. T(s): operation time delay adjusting knob 0.1s~10s
c. Over_t(s): over-voltage operation time delay adjusting knob 0.1s~10s
d. Under_t(s): under-voltage operation time delay adjusting knob 0.1s~10s
e. Asm (%): knob for setting of threshold value of unbalance 5%~15% Over-voltage threshold value = set value × Ue,Under-voltage threshold value = set value × Ue

Wiring diagram of a threephase three-wire system          Wiring diagram of a threephase four-wire system 
Three Phase AC Voltage Monitoring Relay and ProtectorWiring diagram of singlephase and two-phase system     Wiring diagram of a threephase three-wire system 
                                                                                                                                                  (load end protection)

Three Phase AC Voltage Monitoring Relay and Protector
Three Phase AC Voltage Monitoring Relay and ProtectorThree Phase AC Voltage Monitoring Relay and ProtectorThree Phase AC Voltage Monitoring Relay and ProtectorThree Phase AC Voltage Monitoring Relay and ProtectorThree Phase AC Voltage Monitoring Relay and ProtectorQ1.Are you a factory or trading company ?
A:We are a factory founded in 2010 and have over 10 years'OEM and international trading experience .

Q2.What's your main product?
A:Our main products are time Relay, voltage Relay, motor protector, current relay,solid state relay

Q3.Do you accept OEM or ODM?
A:Of course.

Q4.What's your main payment term?
A:T/T ,LC ,D/P.

Q5.Any quality guarantee or after-sales service?
A:All the products have 2 years' Guarantee. If any quality complaint , we will give out solution within 5 days


Q6.Can sample fee be returned back to me ?
A:Sample amount can be deducted from your bulk order payment when order quantity is over 1000 pieces at the first time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier