• Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
  • Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
  • Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
  • Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
  • Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
  • Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay

Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay

Theory: Electromagnetic Relay
Usage: Household Appliances Relay, Communication Relay
Phase: 3
Electricity Type: Ac
Load: Micro Power Relay
Protective Characteristics: Enclosed Rlay
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
ZHRV3-05
Action Principle
Electronic Type
Size
Miniature
Type
Voltage Relay
Rated Frequency
50Hz/60Hz
Name
Voltage Monitoring Relay
Key
Voltage Control Relay
DIN Rail Standard
Width 35mm
Phase Failure and Phase Sequence
<0.5s
Transport Package
Standard Packing
Specification
91.4*36*68mm
Trademark
AKMAN
Origin
China
HS Code
8536490000
Production Capacity
2000PCS/Week

Product Description

Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay

Technical parameters: 
Rated supply voltage P-P: AC 3× 208--3× 440V; P-N: AC 3× 120--3× 254V
Rated supply working voltage range P-P:AV 166V--528V;P-N:AC 96V-329V
Rated supply frequency 50Hz/60Hz
Voltage measurement error ≤1% (Entire setting range)
Delay error ±10%+0.1s
Rated working voltage selection M440:208-220-230-240-380-400-415-440(V)(P-P)
M254:120-127-132-138-220-230-240-254(V)(P-P)
Measuring range AC 166V--528V; AC 96V--329V
Measurement frequency range 45Hz-65Hz
Vlotage threshold range 2%-20%
Unbalance threshold range 5%-15% of rated voltage
Fixed hysteresis rate 2%
Action delay range 0.1s-10s
Reset delay range 0.1s-10s
Knob setting accuracy 1% scale value
Phase failure and phase sequence ≤0.5s
Rated insulation voltage 440V
Contact configuration capacity(A) 2 C/O 8A;1 C/O+1 C/O 5A
IP Class IP20
Class of pollution 3
Electrical Life 105
Mechanical life 106
Altitude ≤2000m
Allowable relative humidity ≤50%(40ºC)(No condensation)
Use category AC-15
Contact capacity Ue/le:250V/1.5A
Output type 2 C/O;1C/O+1 C/O
DIN rail Standard Width 35mm(IEC/EN60715)

Model selection table
Model Overvoltage Undervoltage Asymmetry Trip delay Phase sequence Phase failure Operating voltage Reset time Output Contact Rated operating
Selectable voltage(Un)
ZHRV3-01 - - - 0.1~10s 0.1~10s Z: 2 C/O, M: Mobus+1 C/O A440:         AC(3phase 3wire) 208V, 220V      230V, 240V        380V, 400V 415V, 440V      AN254:       AC(3phase 4wire) 120V, 127V        132V 138V        220V, 230V      240V, 254V
ZHRV3-02 2%~20% - 5%~15% 0.1~10s 0.1~10s
ZHRV3-03 - - - 0.1~10s - 0.1~10s
ZHRV3-04 2%~20% 2%~20% - 0.1~10s - 0.1~10s Z: 2C/O, C: 1C/O+1C/O, Mobus+1C/O
ZHRV3-05 2%~20% 2%~20% - 0.1~10s - 0.1~10s Z: 2C/O, M: Mobus+1C/O
ZHRV3-06 2%~20% 2%~20% 5%~15% 0.1~10s 0.1~10s
ZHRV3-07 2%~20% 2%~20% 5%~15% 0.1~10s 0.1~10s
ZHRV3-08 15% 2%~20%   2s 2s
ZHRV3-09 15% -   2s 2s
ZHRV3-10 15% 15% 8% 2s 2s
ZHRV3-11 15% 15% 8% 2s 2s
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
Features:

Microprocessor base.
Modular design, 36mm width
True RMS measurement, measuring accuracy&less; 1%.
Wide frequency range(45-65Hz) measurement
8 nominal operating voltage selectable
Reset delay adjustable
LED indication for control state
Communication through Modbus module
Applications:

Protection electromechnical device against voltage faults. Protection electromechnical device against reverse running. Protection against a driving load (phase failure) Normal/emergency power supply switching.
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay


Function diagram
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
Wiring Diagram
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control RelayTerminal diagram
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay

Dimensions(mm)

Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
More Products

Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control Relay
Electromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control RelayElectromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control RelayElectromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control RelayElectromechnical Phase Failure Relay 3 Phase Voltage Monitoring Relay Voltage Control RelayQ1.Are you a factory or trading company ?
A:We are a factory founded in 2010 and have over 10 years'OEM and international trading experience .

Q2.What's your main product?
A:Our main products are time Relay, voltage Relay, motor protector, current relay,solid state relay

Q3.Do you accept OEM or ODM?
A:Of course.

Q4.What's your main payment term?
A:T/T ,LC ,D/P.

Q5.Any quality guarantee or after-sales service?
A:All the products have 2 years' Guarantee. If any quality complaint , we will give out solution within 5 days


Q6.Can sample fee be returned back to me ?
A:Sample amount can be deducted from your bulk order payment when order quantity is over 1000 pieces at the first time.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other
Registered Capital
500000 RMB
Plant Area
101~500 square meters