Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay

Theory: Voltage Relay
Usage: Communication Relay
Phase: 3
Electricity Type: Ac
Number of Pole: 3, 4
Size: Miniature
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
ZHRV5-03
Type
Electromagnetic Relay
Rated Frequency
45~65Hz
Rated Operating Voltage Selection
208V-220V-230V-240V-380V-400V-415V-440V
Conventional Thermal Current
6A
Voltage Measuring Error
<1%(Over The Whole Range)
Trip Delay Error
± 10%, +0.1s
Rated Supply Voltage
AC 3*208---3*440V
Voltage Measuring Range
AC 166V--528V
Trip Time for Phase Failure or Incorrect
<0.5s
Rated Operating Voltage Range
AC 166V---528V
Utilisation Category
AC-15, DC-13
Transport Package
Standard Packing
Trademark
AKMAN
Origin
China
HS Code
8537109090
Production Capacity
1000PCS/Week

Product Description

Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay

 Feature:
1, Microprocessor based
2, Modular design, 18mm width
3, True RMS measurement, measuring accuracy≤ 1%
4, Wide frequency range(45-65Hz) measurement
5, 8 nominal operating voltage selectable
6, LED indication for control state
7, Communication through Modbus module

Application:
1, Protection electromechnical device against voltage faults
2, Protection electromechnical device against reverse running
3, Protection against a driving load (phase failure)
4, Normal/emergency power supply switching

Functions:
Phase failure \Phase sequence\ Overvoltage \Undervoltage\ Asymmetry\Trip delay
Model Phase failure Phase sequence Overvoltage Undervoltage Asymmetry Trip delay
ZHRV5-03   √     √ - - - -
ZHRV5-04     √     √ - - 5%~15% 0.1~10s
ZHRV5-05     √ - 2%~20% - - 0.1~10s
ZHRV5-06     √ - - 2%~20% - 0.1~10s
ZHRV5-07     √ - 2%~20% 2%~20% - 0.1~10s
ZHRV5-08     √     √ 2%~20% 2%~20% - 0.1~10s
ZHRV5-09     √     √ 2%~20% 2%~20% 5%~15% 0.1~10s
ZHRV5-10     √     √ 2%~20% 2%~20% 8% 2s
ZHRV5-11     √     √ - - 8% 2s
ZHRV5-12     √     √ 15% 15% 8% 2s

Technical Parameters
Rated supply voltage AC 3*220V--3*460V
Operating voltage range AC 187V-529V
Rated supply frequency 50Hz/60Hz
Phase failure and phase sequence action time ≤0.5s
Measuring range AC 176V--552V
Fixed hysteresis rate 2% of rated operating voltage
Action delay 0.1s~10s
Voltage measurement error ≤1% Entire setting range
Delay error ±10%+0.1s
Knob setting accuracy 1%Scale value
Rated insulation voltage 460V
Contact configuration capacity(A) 8A
IP Class IP20
Class of pollution 3
Electrical Life 105
Mechanical life 106
Altitude ≤2000m
Allowable relative humidity ≤50%(40ºC)(No condensation)
Use category AC-15
Contact capacity Ue/le:250V/1.5A
Output type 1C/O
DIN rail Standard Width 35mm(IEC/EN60715)

Panel Diagram
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay

LED functions
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay

Function diagram
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay
Operating Instructions
1. Set the rated voltage range control knob.
 The position of this knob is only taken into account on energisation of the device.If the switch position is changed while the device is opera-
 ting, all the LEDs fl ash, but the product continues to operate normally with the vol tage selected at the time of energisation preceding the change of position.
 The LED's return to their normal state if the switch is returned to the origin al position selected prior to the last energisation.
2. Set operation threshold value.
3. Set the time delay interval to 0.1s...10s so as to prevent operation in case of transient fault.
4. In case of voltage failure, the relay would be disconnected at the expiration of set time delay interval.
5. If the relay detects voltage failure during electrification, the output relay would be kept in off-state.
6. The measured voltage U <Un*70% indicates open phase fault, and the minimum open phase voltage is 165V.
7. When ZHRV5-03 phase sequence is correct, the output relay would close and the R/T LED would go ON at input voltage (>176V);when ZHRV5-      03 detects phase sequence error and the failure of one or more phases,the output relay would be disconnected,and the R/T LED does not go ON.
8. In case of open phase fault at power input terminals L1 and L2, the function LED would not make indication.

Wiring Diagram                                                                                 Dimensions
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure Relay

Warning
1. This product shall be installed, operated and maintained by professional personnel.
2. Whether or not the product functions normally, user shall not dismantle or repair the said product without permission, and we shall not assume any respon-
 sibility for the accident as a result thereof.
3. Please refer to the wiring diagram in Operation Instructions when arranging wires.
4. Never place power input line in the same conduit with other wires with heavy current. Please use shielded wire if necessary so as not to bring about interfer-
 ence that may influence the normal operation of relay.
5. Do not use this product in areas with dust, corrosive gases and with exposure to direct sunlight and rain.
6. Never use this product in medium with explosion hazard and with gases that may corrode metals and destroy the insulation, and do not use this product in a space
 with conductive dust.
7. Please store and use this product at rated supply voltage and stated temperature, height above sea level and humidity.
8. Failure to follow these instructions can result in death, serious injury, or equipment damage.
9. The warranty period of this product shall be 18 months under normal use.

More products
Three Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure RelayThree Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure RelayThree Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure RelayThree Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure RelayThree Phase AC Voltage Electromagnetic Monitoring Relay Phase Failure RelayQ1.Are you a factory or trading company ?
A:We are a factory founded in 2010 and have over 10 years'OEM and international trading experience .

Q2.What's your main product?
A:Our main products are time Relay, voltage Relay, motor protector, current relay,solid state relay

Q3.Do you accept OEM or ODM?
A:Of course.

Q4.What's your main payment term?
A:T/T ,LC ,D/P.

Q5.Any quality guarantee or after-sales service?
A:All the products have 2 years' Guarantee. If any quality complaint , we will give out solution within 5 days


Q6.Can sample fee be returned back to me ?
A:Sample amount can be deducted from your bulk order payment when order quantity is over 1000 pieces at the first time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other
Registered Capital
500000 RMB
Plant Area
101~500 square meters